The IOCN Mk2 600-051 is a Meggitt vibro-meter IOCN Mk2 VM600 Mk2 input/output and communications interface module acting as the signal and communications interface for a CPUM Mk2 module in a compatible VM600 Mk2 rack.

MODULE TYPEIOCN Mk2 I/O and communications interface
SYSTEM FAMILYVM600 Mk2
OPERATING TEMPERATURE0 to +65°C
ORDERING NUMBER600-051
MANUFACTURERMeggitt vibro-meter
CONDITION / WARRANTYOriginal New · One-Year Warranty
ISO CERTIFICATIONISO-Certified Product
VERIFICATION● Product photos and videos provided after inquiry
REQUEST A QUOTE
MODEL SEARCHFind a specific part numberOpen the best-matched Moore Automation product page directly.
VIBRO-METER ● I/O & COMMUNICATIONS INTERFACE
vibro-meter IOCN Mk2

IOCN Mk2 600-051

600-051 · STANDARD ORDERING NUMBER

6U height · 20 mm width · 125 mm depth · 0.25 kg approx.

MODULE ROLE
IOCN Mk2 600-051 is a Meggitt vibro-meter IOCN Mk2 VM600 Mk2 input/output and communications interface module for the VM600 Mk2 system. It is associated with the standard 600-051 PNR and interfaces compatible CPUM Mk2 processing hardware.
CONFIGURATION NOTE
For IOCN Mk2 600-051, confirm the standard 600-051 PNR, compatible CPUM Mk2 module, rack position, fieldbus cabling, relay wiring and VibroSight configuration before replacement.
👩‍💼
WANT THE BEST PRICE?
Frida
Sales Leader 🏆
EMAILsales5@mooreplc.com WHATSAPP+86 153 5940 8275
ORDER NUMBER BREAKDOWN

How the IOCN Mk2 600-051 reference is identified

IOCN Mk2
Module modelMeggitt vibro-meter IOCN Mk2
600-051
Ordering numberOfficial ordering number 600-051
MANUFACTURER-VERIFIED CHARACTERISTICS

Technical Specifications

Meggitt vibro-meter ↗
IOCN Mk2 I/O & COMMUNICATIONS INTERFACE

Engineering data at a glance

Click “+” to expand more specifications.

HEIGHT6U (262 mm)
WIDTH20 mm (0.8 in)
DEPTH125 mm (4.9 in)
WEIGHT0.25 kg (0.55 lb) approx.
Official Meggitt vibro-meter product data.
Official product verificationVerify the complete ordering reference IOCN Mk2 600-051, including the standard PNR, rack position, CPUM Mk2 partner, fieldbus wiring and VibroSight configuration, against the official Meggitt documentation before installation or replacement.
GENERAL INFORMATION
Brand / product lineMeggitt vibro-meter
Ordering numberIOCN Mk2 600-051
Product typeVM600 Mk2 input/output and communications interface module
System familyCPUM Mk2 / IOCN Mk2 / VM600 Mk2
Module roleSignal and communications interface for the CPUM Mk2 module
Module characteristics6U · 20 mm width · 125 mm depth · 0.25 kg approx.
Operating temperature0 to 65°C (relay-load dependent)
Storage temperature−20 to 85°C
Operating humidity0 to 90% RH, non-condensing
Altitude2,000 m (6,560 ft) maximum altitude
Module and Rack Configuration
System requirementVM600 Mk2 ABE04x rack with compatible CPUM Mk2 processing module
Operating temperature0 to 65°C operation; −20 to 85°C storage
Module environmentIndoor use · OVC II · pollution degree 2 · up to 2,000 m altitude
System Integration and Installation
Module roleSignal and communications interface for the CPUM Mk2 module
Compatible systemVM600 Mk2 ABE04x rack with CPUM Mk2 processing module
Companion modulesCPUM Mk2; two matched pairs are required for redundant operation
Module interface2 system Ethernet ports · 2 fieldbus ports · 2 configurable relays
Configuration softwareVibroSight software via Ethernet
Environmental and Mechanical Data
Verified IOCN Mk2 characteristics: 6U height · 20 mm width · 125 mm depth · 0.25 kg approx. Official source: Parker Meggitt data sheet DS 268-135 for the VM600 Mk2 CPUM Mk2 + IOCN Mk2 module.
FAQ

Questions Buyers Ask Most

What role does IOCN Mk2 600-051perform in a VM600 Mk2 rack?

IOCN Mk2 600-051 acts as the signal and communications interface for the CPUM Mk2 processing module, supporting rack data aggregation, fieldbus communication, system Ethernet links and status indication.

Which processing module must IOCN Mk2 600-051be paired with?

IOCN Mk2 600-051 is designed to operate with a compatible CPUM Mk2 processing module in a VM600 Mk2 ABE04x rack. Confirm the rack slot, module versions and VibroSight project before commissioning.

Which network interfaces are available on IOCN Mk2 600-051?

IOCN Mk2 600-051 provides two system Ethernet connections, two Ethernet fieldbus ports and two serial RS-485 fieldbus ports. Use only the connector and protocol combination supported by the configured application.

Which fieldbus protocols does IOCN Mk2 600-051support?

IOCN Mk2 600-051 supports Modbus TCP through Ethernet and PROFIBUS DP-V0 server operation through RS-485. The official data sheet states that Modbus RTU is not currently supported.

What relay outputs are provided by IOCN Mk2 600-051?

IOCN Mk2 600-051 includes two user-configurable SPDT relays, each providing COM, NC and NO contacts. They indicate system status or alarms and are not protective relays for initiating a machine trip.

What environmental limits apply to IOCN Mk2 600-051?

IOCN Mk2 600-051 is specified for 0 to 65°C operation, subject to relay loading, −20 to 85°C storage, non-condensing humidity and indoor use up to 2,000 m altitude.

What should be checked before replacing IOCN Mk2 600-051?

IOCN Mk2 600-051 requires verification of the complete 600-051 PNR, CPUM Mk2 partner, rack position, fieldbus and Ethernet wiring, relay connections, module redundancy requirements and VibroSight configuration.

CONTACT PRODUCT SPECIALIST

Check your configuration with Frida

Share the complete ordering code, installed rack, module versions, communications wiring and application details for compatibility, availability and lead-time checking.

CHOOSE A DIRECT CONTACT METHOD
DATA SHEET

Official Datasheet and References for
IOCN Mk2 600-051

Official Meggitt documentation for the VM600 Mk2 IOCN Mk2 input/output family and the 600-051 hardware variant.

Meggitt vibro-meter IOCN Mk2

Meggitt maps the IOCN Mk2 600-051 PNR to the underlying 600-051-000-vvv module version. The 600-051 PNR identifies the standard IOCN Mk2 version and corresponds to the underlying 600-051-000-vvv module version, where vvv represents hardware versions used by the finished product.

OFFICIAL DATASHEET

Contact to Get Support

Send the complete model, quantity, and your technical or purchasing question.

Technical statements on this product page are based on publicly available official Meggitt manufacturer documentation.

IOCN Mk2 SYSTEM RELATIONSHIP FAMILY

How IOCN Mk2 600-051 Fits the vibro-meter Measurement Chain

Meggitt vibro-meter is the product line; IOCN Mk2 is the IOCN Mk2 VM600 Mk2 input/output and communications interface module; and IOCN Mk2 600-051 is the official ordering reference for the configured VM600 Mk2 system.

Meggitt vibro-meter · PRODUCT LINE
IOCN Mk2 IOCN Mk2 VM600 Mk2 input/output and communications interface moduleVM600 Mk2 machinery protection and monitoring system · MODULE ROLE
MODULE MODEL

IOCN Mk2 · 600-051

The IOCN Mk2 600-051 acts as the signal and communications interface for the CPUM Mk2 processing module in a configured VM600 Mk2 rack.

SYSTEM FAMILY

IOCN Mk2 · CPUM Mk2 · VibroSight

The VM600 Mk2 system uses IOCN Mk2 with a compatible CPUM Mk2 processing module and VibroSight configuration. Match the rack, module versions and project settings.

MODULE CHARACTERISTICS

6U · 20 mm × 125 mm · 0.25 kg approx.

The module provides two system Ethernet ports, two fieldbus interfaces and two configurable relays; confirm the rack position, wiring and hardware version.

Compatibility check: verify the standard 600-051 PNR, compatible CPUM Mk2 module, VM600 Mk2 rack position, Ethernet and fieldbus cabling, relay wiring and VibroSight configuration before installation or replacement.
APPLICATION AREAS

Application mind map for IOCN Mk2 600-051

Rack Controller InterfaceSignal and communications interface for the CPUM Mk2 processing module
Fieldbus CommunicationsModbus TCP and PROFIBUS DP communications for external systems
APPLICATION CENTERIOCN Mk2 600-051IOCN Mk2 VM600 Mk2 input/output and communications interface module
System Ethernet IntegrationUse the system Ethernet interfaces with VibroSight software or XMx16 + XIO16T modules
Replacement VerificationConfirm the 600-051 PNR, rack slot, CPUM Mk2 partner, fieldbus wiring and VibroSight configuration
ABOUT MOORE AUTOMATION

A trusted industrial automation sourcing partner

Moore Automation Limited supplies industrial automation spare parts to customers worldwide, with dedicated sourcing, part-number verification, pre-shipment confirmation and responsive sales support.

Global sourcing Pre-shipment verification One-year warranty
SERVICE

Industrial Automation Order Support

A clear workflow for sourcing, verification, shipment preparation, delivery and product assurance.

STAGESERVICE ACTIONWHAT WE CHECK OR PROVIDE
01PROCUREMENT
Product SourcingCurrent, hard-to-find and discontinued industrial automation parts.
02VERIFICATION
Part Number ReviewComplete model, suffix, nameplate, visible revision and application details.
03CONFIRMATION
Pre-Shipment CheckModel, label, condition and packaging confirmed with actual photos or video.
04FULFILLMENT
Global Delivery
Worldwide delivery with flexible shipping options. We support door-to-door pickup or delivery to your nominated freight forwarder in China.
DHLFedExUPSTNT
05ASSURANCE
One-Year WarrantyOne-year warranty from delivery for products supplied by Moore Automation.
Warranty Claim Information
What to provide: If a product-related issue occurs within the warranty period, contact our team and submit one clear, continuous video for review.
Complete product and nameplate
Power supply and wiring connections
Installation and operating conditions
Indicator lights, alarms or error messages
Clear description of the fault
Continuous video showing the issue
Review outcome: If the evidence confirms a covered product fault, Moore Automation will arrange the appropriate warranty solution.
SALES ASSISTANCE

Contact Sales Manager Frida

Include the complete part number, quantity and delivery destination.

EMAILsales5@mooreplc.com WHATSAPP+86 153 5940 8275
Customers Also Source from Moore

Hot-selling Models

Select a brand to view models
OTHER BRANDSAdditional industrial automation models
OTHER BRANDS75SCLIndustrial Automation Part
OTHER BRANDS922AB2K‐C6PIndustrial Automation Part
OTHER BRANDS998MXIndustrial Automation Part
OTHER BRANDS4208SNIndustrial Automation Part
OTHER BRANDS5894PIIndustrial Automation Part
OTHER BRANDS34710Industrial Automation Part
OTHER BRANDS73073D3Industrial Automation Part
OTHER BRANDS73091BIndustrial Automation Part
OTHER BRANDS1001573Industrial Automation Part
OTHER BRANDS8EP276A-UKIndustrial Automation Part
OTHER BRANDS23001-069Industrial Automation Part
OTHER BRANDSSLXPC-P2-MB-BN-12Industrial Automation Part
leave a message
If you are interested in our products and want to know more details, please leave a message here, we will reply you as soon as we can.
  • PLC
  • DCS
  • TSI
  • HMIS
Related Products