banner
Products
Home /

DCS

/T7481 - ICS Monitored Guarded Output Module
T7481
T7481
T7481

T7481 - ICS Monitored Guarded Output Module

The T7481 is a 24 VDC Monitored Guarded Output Module designed for safety-critical output applications
  • Brand :

    ICS
  • Part Number :

    T7481
  • Weight :

    1.6 kg
  • Dimension :

    3.3x26.4x32.7cm
  • Country of Origin :

    USA
  • HS Code :

    8537101190
  • Description :

    Monitored Guarded Output Module

ICS T7481 Monitored Guarded Output Module


Sales Manager: Frida


Email: sales5@mooreplc.com


Phone/ Whatsapp: +86 15359408275




T7481 Description

The T7481 is a 24 VDC Monitored Guarded Output Module designed for safety-critical output applications. It provides 16 guarded outputs (in two groups of eight) with built-in line monitoring for open and short circuits. The module features a dual-redundant design ensuring that no single fault within the module can inadvertently apply power to an output. It is hot-replaceable and supports fail-safe (single module) or fault-tolerant (dual module parallel) configurations. The module is TÜV certified to Risk Class 5.



T7481 Parameter

Supply Voltage Range:18 to 36 VDC
Number of Outputs:16 (two groups of 8)
Load Current per Point (0–40°C):2 A
Load Current per Point (at 60°C):1.5 A (derated)
Minimum Load Current:20 mA (5 mA for T7481A)
On-State Voltage Drop:1.0 V (max)
Off-State Leakage Current (Single Module):5 mA max
Off-State Leakage Current (Dual Modules):7.5 mA max
Surge Current (Peak):3.5 A (incandescent/capacitive/inductive)
Electrical Isolation:2500 V (field to logic)


FAQ

Q:What is the minimum load current for the T7481?
A:T7481: 20 mA
T7481A: 5 mA
If the load is smaller than specified, the off-state leakage current may prevent the load from turning off completely.

Q:Can I use a single T7481 for safety-critical applications?
A:Yes. A single module provides fail-safe operation – any single failure will cause the output to turn off (de-energize to trip).

Q:How do I achieve fault tolerance?
A:Connect two T7481 modules in parallel and configure them for Dual Mode in the I/O configuration editor. This allows one module to be removed/replaced without interrupting load control.

Q:What happens if field power is not connected?
A:All outputs in the affected group will indicate a load/fuse fault because the output circuit testing monitors current flow.

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit yourenquiry and one of our specialists will source it for you.


Email: sales5@mooreplc.com


Phone/ Whatsapp: +86 15359408275



How we appeal clients?

1)Inventory: A wide range of new and discontinued parts for a wide range of labels.
1)We have a strong inventory of more than ten brands in stock. I will provide you with the best price and the shortest delivery time.
2)Shipment:DHL,UPS,TNT,CHIRLINE,FEDEX
3) Speed: Fast response and efficient delivery.
4)Professional: Solid business organization
5)International: A network of global partners and preferred suppliers.

Hot selling products

T3310
T3419
T8151C
T8310C
T8311C
T8431
T8461C
7400206-100
CM 3201
T3401
T3411F
T3420A
T3480
T3481
T3481A
T7481A
T8110B
T8122
T8151B
T8153C
T8232
T8310
T8403
T8403C
T8461
T9110
T9300
T9402
T9432
T9451
T9802
T9832
T9852

leave a message
If you are interested in our products and want to know more details, please leave a message here, we will reply you as soon as we can.
  • PLC
  • DCS
  • TSI
  • HMIS

New Products

Related Products