GE MARK V · COMMON ANALOG I/O BOARD

DS200TCCAG1B

DS200TCCAG1B is a GE common analog I/O board that conditions current-loop, temperature and shaft-monitoring signals for the Mark V turbine control system.

PRODUCT TYPECOMMON ANALOG I/O BOARD
PLATFORMMark V
CURRENT I/O4–20 mA
TEMPERATURERTD / TC
MANUFACTURERGE
CONDITION / WARRANTYOriginal New · One-Year Warranty
ISO CERTIFICATIONISO-Certified Product
VERIFICATION● Product photos and videos provided after inquiry
REQUEST A QUOTE
MODEL SEARCHFind a specific part numberOpen the best-matched Moore Automation product page directly.
GE ● COMMON ANALOG I/O BOARD
Mark V

DS200TCCAG1B

COMMON ANALOG I/O BOARD

MARK V · COMMON ANALOG I/O BOARD

MODULE ROLE
DS200TCCAG1B scales and conditions analog signals received through CTBA, TBQA and TBCA field termination boards, and transfers the resulting data over the 3PL interface.
LONG DESCRIPTION
DS200TCCAG1B processes 4–20 mA inputs and outputs, RTD and thermocouple temperature inputs, and shaft-voltage/current signals. CTBA supplies the current-loop and shaft-monitoring signal paths; TBCA supplies RTD inputs; TBQA supplies thermocouple and cold-junction information. The conditioned values are transferred through 3PL to the I/O engine. Hardware jumpers support the serial test port, oscillator test and factory-test functions, while the installed I/O configuration defines signal scaling.
👩‍💼
WANT THE BEST PRICE?
Frida
Sales Leader 🏆
EMAILsales5@mooreplc.com WHATSAPP+86 153 5940 8275
ORDER NUMBER BREAKDOWN

How the DS200TCCAG1B Reference Is Structured

DS
ManufacturerGE, Salem, Virginia
200
Assembly levelBase-level board
TCCA
Functional acronymcommon analog i/o board
G1
Group variationGroup 1
B
Functional revisionFirst functional revision B
MANUFACTURER-REFERENCE CHARACTERISTICS

Technical Specifications

GE Mark V ↗
DS200TCCAG1B COMMON ANALOG I/O BOARD

Engineering data at a glance

Click “+” to expand more specifications.

CURRENT I/O4–20 mA
TEMPERATURERTD / TC
DATA BUS3PL
SHAFT INPUTSV / I
Engineering functions and interfaces follow the referenced manufacturer documentation.
Configuration note Match the complete assemblyDS200TCCAG1B, installed system interfaces and application-specific configuration.
GENERAL INFORMATION −
BrandGE
Part numberDS200TCCAG1B
Product typeCommon Analog I/O Board
Current-loop interface4–20 mA inputs and outputs
Temperature inputsRTD and thermocouple
Shaft monitoringVoltage and current inputs
FIELD CONNECTIONS +
JAA / JBBCTBA current-output and current-input/shaft-signal paths
JCC / JDDRTD inputs from TBCA
JAR/S/TThermocouple and cold-junction signals from TBQA
CONTROL INTERFACES +
3PLConditioned-data interface to STCA / I/O engine
2PLPower distribution from TCPS
J1 / JP2 / JP3Serial-port, oscillator-test and factory-test jumpers
FUNCTIONAL CONTEXT +
System role: TCCA supplies scaling and conditioning for the common analog signal paths. Current-loop, temperature and shaft-monitoring selections are defined by the installed I/O configuration and their respective field termination boards.
Source:GEH-6153, Chapter 4 pages 4-11–4-12, TCCA; GEH-6195F TCCA configuration
FAQ

Questions Buyers Ask Most

Which signals are handled by DS200TCCAG1B?+

DS200TCCAG1B handles 4–20 mA inputs and outputs, RTD and thermocouple inputs, and shaft voltage/current monitoring. The field circuits connect through the appropriate CTBA, TBQA or TBCA termination board.

Which termination boards connect to DS200TCCAG1B?+

DS200TCCAG1B uses CTBA for current-loop and shaft-monitoring paths, TBCA for RTD inputs, and TBQA for thermocouple and cold-junction information. Each path has a distinct connector assignment.

How does DS200TCCAG1B transfer conditioned data?+

DS200TCCAG1B uses the 3PL data-bus connection to transfer scaled and conditioned signals to the associated STCA and I/O engine. The 2PL connection supplies power from TCPS.

What is JAA used for on DS200TCCAG1B?+

DS200TCCAG1B carries the 4–20 mA output signals to CTBA through JAA. JBB is the separate connection used for current inputs and shaft-voltage/current signals from CTBA.

How are RTD inputs connected to DS200TCCAG1B?+

DS200TCCAG1B reads RTD signals from TBCA through JCC and JDD. Its circuitry provides RTD excitation, measures the resulting signal and applies the configured temperature scaling.

How are thermocouple signals processed by DS200TCCAG1B?+

DS200TCCAG1B uses thermocouple inputs and cold-junction information from TBQA to calculate compensated temperature values. The installed I/O configuration selects the thermocouple type and associated curve.

CONTACT PRODUCT SPECIALIST

Check your configuration with Frida

Share the complete order number and application details for compatibility, availability and lead-time checking.

CHOOSE A DIRECT CONTACT METHOD
DATA SHEET

Product Information for
DS200TCCAG1B

Official manufacturer-documentation status for GE DS200TCCAG1B.

Official datasheet status

No current official DS200TCCAG1B product datasheet was located in the manufacturer's public documentation. For product documentation and compatibility details, please contact Product Specialist Frida.

CONTACT FRIDA

Contact to Get Support

Send the complete model, quantity, and your technical or purchasing question.

No working manufacturer-hosted instruction or datasheet PDF was confirmed; contact Frida for the applicable document.

GE MARK V SYSTEM RELATIONSHIP

How DS200TCCAG1B Fits Mark V

GE is the manufacturer brand; GE Mark V is the product family; and DS200TCCAG1B is the common analog i/o board.

GE · BRAND
GE Mark VCommon Analog I/O Board
SYSTEM ROLE

Current I/O

scales and conditions analog signals received through CTBA, TBQA and TBCA field termination boards, and transfers the resulting data over the 3PL interface.

MODULE / CONFIGURATION

Field Connections

CTBA current-output and current-input/shaft-signal paths

ASSEMBLY FORMAT

DS200TCCAG1B · TCCA Board

GE Mark V common analog i/o board.

System relationship: scales and conditions analog signals received through CTBA, TBQA and TBCA field termination boards, and transfers the resulting data over the 3PL interface.
APPLICATION AREAS

Application map for DS200TCCAG1B

Process Current LoopsCondition 4–20 mA inputs and drive monitoring outputs
Temperature MonitoringProcess RTD and thermocouple field signals
Mark V DS200TCCAG1B DS200TCCAG1B · Common Analog I/O Board
Shaft MonitoringAcquire shaft-voltage and shaft-current signals
Common Analog DataTransfer conditioned measurements through the 3PL interface
ABOUT MOORE AUTOMATION

A trusted industrial automation sourcing partner

Moore Automation Limited supplies industrial automation spare parts to customers worldwide, with dedicated sourcing, part-number verification, pre-shipment confirmation and responsive sales support.

Global sourcing Pre-shipment verification One-year warranty
SERVICE

Industrial Automation Order Support

A clear workflow for sourcing, verification, shipment preparation, delivery and product assurance.

STAGESERVICE ACTIONWHAT WE CHECK OR PROVIDE
01PROCUREMENT
Product SourcingCurrent, hard-to-find and discontinued industrial automation parts.
02VERIFICATION
Part Number ReviewComplete model, suffix, nameplate, visible revision and application details.
03CONFIRMATION
Pre-Shipment CheckModel, label, condition and packaging confirmed with actual photos or video.
04FULFILLMENT
Global Delivery
Worldwide delivery with flexible shipping options. We support door-to-door pickup or delivery to your nominated freight forwarder in China.
DHLFedExUPSTNT
05ASSURANCE
One-Year WarrantyOne-year warranty from delivery for products supplied by Moore Automation.
Warranty Claim Information+
What to provide: If a product-related issue occurs within the warranty period, contact our team and submit one clear, continuous video for review.
✓Complete product and nameplate
✓Power supply and wiring connections
✓Installation and operating conditions
✓Indicator lights, alarms or error messages
✓Clear description of the fault
✓Continuous video showing the issue
Review outcome: If the evidence confirms a covered product fault, Moore Automation will arrange the appropriate warranty solution.
SALES ASSISTANCE

Contact Sales Manager Frida

Include the complete part number, quantity and delivery destination.

EMAILsales5@mooreplc.com WHATSAPP+86 153 5940 8275
Same-brand recommendations

GE Related Models

GE ↗PACSystems and Field Control models
Customers Also Source from Moore

Hot-selling Models

Select a brand to view models
OTHER BRANDSSelected automation and instrumentation models
ROSEMOUNT3051CG3APressure Transmitter
ROSEMOUNT3051CG4A22APressure Transmitter
ENDRESS+HAUSERCLD18Conductivity Measuring System
ENDRESS+HAUSERCLS15-A1A1AConductivity Sensor
ENDRESS+HAUSERCLS50D-AA2C21Conductivity Sensor
ENDRESS+HAUSERCLS54Conductivity Sensor
ENDRESS+HAUSERCOS61D-1020/0Dissolved Oxygen Sensor
ENDRESS+HAUSERCPM253-CP00015pH/ORP Transmitter
ACCUENERGYIIR-M-RCT-P1Power and Energy Meter
OMRONCJ1W-DA021Analog Output Unit
OMRONCJ1W-DA041Analog Output Unit
OMRONCJ1W-ID261Digital Input Unit
leave a message
If you are interested in our products and want to know more details, please leave a message here, we will reply you as soon as we can.
  • PLC
  • DCS
  • TSI
  • HMIS
Related Products